Frederiksburg server room
This documentation is only visible to GBIF staff. |
The server room is L115 in Thorvaldsensvej 40, Institut for Plante- og Miljøvidenskab. Access is with a guest card available by prior arrangement from the Ferderiksberg IT support desk.
Each rack is supplied with a 32A power distribution unit (PDU) on each side, one side has UPS, the other does not.
Each PDU is split into two groups (I think) of three phases, each phase-group (white/grey/black) can supply 20A at 230V. The display on the power strip gives the current draw.
Left Rack (???)
U | Server | Network | Power | Purpose |
---|---|---|---|---|
42 |
||||
41 |
⤓ |
|||
40 |
||||
39 |
⤓ |
|||
38 |
||||
37 |
⤓ |
|||
36 |
||||
35 |
⤓ |
|||
34 |
||||
33 |
⤓ |
|||
32 |
||||
31 |
⤓ |
|||
30 |
||||
29 |
⤓ |
|||
28 |
||||
27 |
⤓ |
|||
26 |
||||
25 |
⤓ |
|||
24 |
||||
23 |
⤓ |
|||
22 |
||||
21 |
⤓ |
|||
20 |
||||
19 |
⤓ |
|||
18 |
||||
17 |
⤓ |
|||
16 |
||||
15 |
⤓ |
|||
14 |
DBorVM |
2×25Gb/s + 1×1Gb/s |
2×1000W |
- |
13 |
⤓ |
|||
12 |
DBorVM |
2×25Gb/s + 1×1Gb/s |
2×1000W |
- |
11 |
⤓ |
|||
10 |
DBorVM |
2×25Gb/s + 1×1Gb/s |
2×1000W |
- |
9 |
⤓ |
|||
8 |
C8N3 |
2×25Gb/s + 1×1Gb/s |
2×2000W |
C8 cluster node |
7 |
⤓ |
|||
6 |
C8N2 |
2×25Gb/s + 1×1Gb/s |
2×2000W |
C8 cluster node |
5 |
⤓ |
|||
4 |
C8N1 |
2×25Gb/s + 1×1Gb/s |
2×2000W |
C8 cluster node |
3 |
⤓ |
|||
2 |
C8N4 |
2×25Gb/s + 1×1Gb/s |
2×2000W |
C8 cluster node |
1 |
⤓ |
Middle Rack (???)
U | Server | Network | Power | Purpose |
---|---|---|---|---|
42 |
||||
41 |
⤓ |
|||
40 |
||||
39 |
⤓ |
|||
38 |
||||
37 |
⤓ |
|||
36 |
||||
35 |
⤓ |
|||
34 |
||||
33 |
⤓ |
|||
32 |
||||
31 |
⤓ |
|||
30 |
||||
29 |
⤓ |
|||
28 |
||||
27 |
⤓ |
|||
26 |
||||
25 |
⤓ |
|||
24 |
||||
23 |
⤓ |
|||
22 |
||||
21 |
⤓ |
|||
20 |
||||
19 |
⤓ |
|||
18 |
||||
17 |
⤓ |
|||
16 |
||||
15 |
⤓ |
|||
14 |
DBorVM |
2×25Gb/s + 1×1Gb/s |
2×1000W |
- |
13 |
⤓ |
|||
12 |
DBorVM |
2×25Gb/s + 1×1Gb/s |
2×1000W |
- |
11 |
⤓ |
|||
10 |
DBorVM |
2×25Gb/s + 1×1Gb/s |
2×1000W |
- |
9 |
⤓ |
|||
8 |
C8N8 |
2×25Gb/s + 1×1Gb/s |
2×2000W |
C8 cluster node |
7 |
⤓ |
|||
6 |
C8N7 |
2×25Gb/s + 1×1Gb/s |
2×2000W |
C8 cluster node |
5 |
⤓ |
|||
4 |
C8N6 |
2×25Gb/s + 1×1Gb/s |
2×2000W |
C8 cluster node |
3 |
⤓ |
|||
2 |
C8N5 |
2×25Gb/s + 1×1Gb/s |
2×2000W |
C8 cluster node |
1 |
⤓ |
Right rack (???)
U | Server | Network | Power | Purpose |
---|---|---|---|---|
42 |
||||
41 |
⤓ |
|||
40 |
||||
39 |
⤓ |
|||
38 |
||||
37 |
⤓ |
|||
36 |
||||
35 |
⤓ |
|||
34 |
||||
33 |
⤓ |
|||
32 |
||||
31 |
⤓ |
|||
30 |
||||
29 |
⤓ |
|||
28 |
||||
27 |
⤓ |
|||
26 |
||||
25 |
⤓ |
|||
24 |
||||
23 |
⤓ |
|||
22 |
||||
21 |
⤓ |
|||
20 |
||||
19 |
⤓ |
|||
18 |
||||
17 |
⤓ |
|||
16 |
||||
15 |
⤓ |
|||
14 |
DBorVMorNFS |
2×25Gb/s + 1×1Gb/s |
2×1000W |
- |
13 |
⤓ |
|||
12 |
DBorVMorNFS |
2×25Gb/s + 1×1Gb/s |
2×1000W |
- |
11 |
⤓ |
|||
10 |
DBorVMorNFS |
2×25Gb/s + 1×1Gb/s |
2×1000W |
- |
9 |
⤓ |
|||
8 |
C8N12 |
2×25Gb/s + 1×1Gb/s |
2×2000W |
C8 cluster node |
7 |
⤓ |
|||
6 |
C8N11 |
2×25Gb/s + 1×1Gb/s |
2×2000W |
C8 cluster node |
5 |
⤓ |
|||
4 |
C8N10 |
2×25Gb/s + 1×1Gb/s |
2×2000W |
C8 cluster node |
3 |
⤓ |
|||
2 |
C8N9 |
2×25Gb/s + 1×1Gb/s |
2×2000W |
C8 cluster node |
1 |
⤓ |